Configuring the snmp agent to send traps to a host – H3C Technologies H3C SecPath F1000-E User Manual
Page 150
139
To generate linkUp or linkDown traps when the link state of an interface changes, enable the linkUp or
linkDown trap function both globally by using the snmp-agent trap enable [ standard [ linkdown |
linkup ] * ] command and on the interface by using the enable snmp trap updown command.
After you enable a trap function for a module, whether the module generates traps also depends on the
configuration of the module. For more information, see the configuration guide for each module.
To enable traps:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable the trap
function globally.
snmp-agent trap enable [bfd | bgp | configuration |
flash | ospf [ process-id ] [ ifauthfail | ifcfgerror |
ifrxbadpkt | ifstatechange | iftxretransmit |
lsdbapproachoverflow | lsdboverflow | maxagelsa |
nbrstatechange | originatelsa | vifcfgerror |
virifauthfail | virifrxbadpkt | virifstatechange |
viriftxretransmit | virnbrstatechange ] * | pim
[ candidatebsrwinelection | electedbsrlostelection |
interfaceelection | invalidjoinprune | invalidregister |
neighborloss | rpmappingchange ] * | standard
[ authentication | coldstart | linkdown | linkup |
warmstart ] * | system | vrrp [ authfailure |
newmaster ] ]
Optional.
By default, only the trap
function of the voice
module is disabled. The
trap function of other
modules is enabled.
3.
Enter interface view.
interface interface-type interface-number N/A
4.
Enable link state
traps.
enable snmp trap updown
Optional.
By default, the link state
traps are enabled.
Configuring the SNMP agent to send traps to a host
The SNMP module buffers the traps received from a module in a trap queue. You can set the size of the
queue, the duration that the queue holds a trap, and trap target (destination) hosts, typically the NMS.
To successfully send traps, you must also perform the following tasks:
•
Complete the basic SNMP settings and verify that they are the same as on the NMS. If SNMPv1 or
SNMPv2c is used, you must configure a community name. If SNMPv3 is used, you must configure
an SNMPv3 user and MIB view.
•
Make sure the device and the NMS can reach each other.
To configure the SNMP agent to send traps to a host:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS