Configuring global parameters for session logging, Log report – H3C Technologies H3C SecPath F1000-E User Manual
Page 101
90
Table 15 Configuration items
Item Description
Source Zone
Specify the source zone and destination zone.
You can configure an optional security zone on the page entered by selecting
System > Zone.
Destination Zone
ACL
Specify the ACL for filtering log entries, and only log entries permitted by the
ACL will be output.
The rules of the specified ACL can be configured on the page entered by
selecting Firewall > ACL.
Configuring global parameters for session logging
Select Log Report > Session Log > Global Setup from the navigation tree to enter the page as shown
in
.
Figure 35 Global configuration page
Table 16 Configuration items
Item
Description
Time Threshold
Set the time threshold for outputting session logging entries.
With this argument set, log entries will be output for sessions whose lifetimes
reach the specified time threshold.
Traffic Threshold
Set the traffic threshold for outputting session logging entries. It can be in
number of packets or bytes.
With the traffic threshold set, log entries will be output for sessions whose
traffic reaches the specified threshold in number of bytes or packets.
Output Log Entries for Session
Creation
Select this option to output a log entry when a session is created.
Output Log Entries for Session
Deletion
Select this option to output a log entry when a session is deleted.
Log report
The log report module allows you to view the log information on the device.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS