Configuring the rmon ethernet statistics function, Configuring the rmon history statistics function, Configuring the rmon alarm function – H3C Technologies H3C SecPath F1000-E User Manual
Page 137: Configuring the rmon ethernet statistics, Function
126
Configuring the RMON Ethernet statistics function
Step Command
1.
Enter system view.
system-view
2.
Enter Ethernet interface view.
interface interface-type interface-number
3.
Create an entry in the RMON statistics
table.
rmon statistics entry-number [ owner text ]
You can create one statistics entry for each interface, and up to 100 statistics entries on the device. After
the entry limit is reached, you cannot add new entries.
Configuring the RMON history statistics function
Follow these guidelines when you configure RMON history statistics function:
•
The entry-number for an RMON history control entry must be globally unique. If an entry number
has been used on one interface, it cannot be used on another.
•
You can configure multiple history control entries for one interface, but must make sure their entry
numbers and sampling intervals are different.
•
The device supports up to 100 history control entries.
•
You can successfully create a history control entry, even if the specified bucket size exceeds the
history table size supported by the device. However, the effective bucket size will be the actual value
supported by the device.
To configure the RMON history statistics function:
Step Command
1.
Enter system view.
system-view
2.
Enter Ethernet interface view.
interface interface-type interface-number
3.
Create an entry in the RMON history
control table.
rmon history entry-number buckets number interval
sampling-interval [ owner text ]
Configuring the RMON alarm function
Follow these guidelines when you configure the RMON alarm function:
•
To send traps to the NMS when an alarm is triggered, configure the SNMP agent as described in
"Configuring SNMP" before configuring the RMON alarm function.
•
If the alarm variable is a MIB variable defined in the history group or the Ethernet statistics group,
make sure the RMON Ethernet statistics function or the RMON history statistics function is
configured on the monitored Ethernet interface. Otherwise, even if you can create the alarm entry,
no alarm event can be triggered.
•
You cannot create a new event, alarm, or private alarm entry that has the same set of parameters
as an existing entry. For parameters to be compared for duplication, see
.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS