beautypg.com

2 connection cables, 6wiring, 3 wiring guidelines – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 98

background image

6.3

Wiring guidelines

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-8

6.3.2

Connection cables

Connection cables

6-

][Verdr_Leiterquerschnitte_DD5

Single-axis systems

We recommend the following cable cross sections in accordance with
EN 60204:

* North America: max. 39 m length, Europe: up to max. length

Connection

Pin designation

Cable cross section

Conditions

Mains voltage AC

X0

1.5 mm²

600 V

DC intermediate circuit
Brake resistor

X8

1.5 mm²

1000 V, shielded for lengths
> 20 cm

Motor cables without
choke, max. 25 m

X9

1.5 mm²

600 V, shielded,
C < 150 pF/m

Motor cables with choke, 25
– 50 m*

X9

1 mm²

600 V, shielded,
C < 150 pF/m

Resolver, thermal switch,
max.100 m*

X2

4x2x0.25 mm²

Twisted pair,
shielded, C < 120 pF/m

Encoder, thermal switch,
Max. 50 m*

X1

7x2x0.25 mm²

Twisted pair, shielded

Incremental encoder, ther-
mal switch,
Max. 25 m

X1

8x2x0.25 mm²

Twisted pair, shielded

Analogue inputs, AGND,
max 30 m

X3

0.25 mm²

Twisted pair, shielded

Digital inputs and outputs,
BTB, DGND, max. 30 m

X3

0.5 mm²

Holding brake (motor):

X9

Min. 0.75 mm

2

600 V, shielded, check volt-
age drop

+24 V/DGND

X4

Max. 2.5 mm²

Check voltage drop