4.6
Implementation of stop categories
4
Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-50
Wiring suggestion
Implementation of Category 0 E-STOP, control function with auxiliary
contactors
Fig. 4-18:
Stop Category 0
][Funktion_Stopp_Motorleistung
S1: On
S2: Off
S3: E-STOP
or
S1
S2
S3
BTB