beautypg.com

Safety during operation, 3safety, 2 safety during operation – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 23

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

3-5

3.2

Safety during operation

3

Safety

3.2

Safety during operation

3200

Safety during operation

3-

][Sicherheit_Bestimmung_Betrieb_1

While the units are in operation there is a risk of death or serious injury
and material damage.

Do not open or touch the units during operation.

Keep all covers and cabinet doors closed during operation.

When the units are switched on, they should only be touched during
commissioning by qualified staff.

During operation the servo amplifiers may contain live, uninsulated
components, depending on their protection type.

Control and power connections may still carry voltage, even when the
motor is not rotating.

Surfaces on the servo amplifiers may become hot during operation.
Temperatures may reach more than 80° C.

Sicherheit_Bestimmung_Betrieb_DD5

In unfavourable conditions arcing may occur, causing potential injury to
persons and damage to electrical contacts.

For this reason, never unplug the electrical connections on the servo
amplifier while voltage is applied.

After disconnecting the servo amplifier from the mains voltages, wait
at least five minutes before touching any parts that carry voltage (e.g.
contacts) or loosening the connections.

After the mains voltages have been switched off, capacitors continue
to carry hazardous voltages for up to 5 min.

To be safe, measure the voltage in the intermediate circuit and wait
until the voltage has dropped below 40 VDC.

DANGER!

DANGER!