2 overview, Unit structure, 1 unit features – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 11: 1 power element, 2overview, 1 unit structure

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-1
2.1
Unit structure
2
Overview
22000
Overview
Overview
2-
2.1
Unit structure
2100
Unit structure
2-
2.1.1
Unit features
Unit features
2-
][Ueber_Geraeteaufbau_DD5
The compact servo amplifier PMCtendo DD5 consists of
A
power element
A
control element with
– Inputs and outputs
– Sequence control
– Control loops for current, speed and position
– Interfaces for communication with the periphery
Unit types:
Units with various mains voltages and output currents
2.1.1.1
Power element
Power element
2-
Ueber_Merkmale_Leistungsteil_DD5
The servo amplifier's power element has the following features:
Connection to earthed three-phase supplies, rated voltage range and
continuous output current:
– 230V series: 1 x 110 V - 3 x 230 V (3 A, 6 A, 10 A)
– 480V series: 3 x 208 V – 3 x 480 V (1,5 A, 3 A, 6 A)
TN network and TT network with earthed star point, symmetrical rated
current, connection to other networks only with isolating transformer
B6 rectifier bridge integrated directly on the three-phase, earthed net-
work, mains filter and start-up circuit
Single-phase supply possible (e.g. for commissioning or set-up
mode)
Fuse protection (e.g. blow-out fuse) through user
All shield connections directly on the servo amplifier
Max. intermediate circuit voltage in generator mode:
– 230V series: 135 – 450 VDC
– 480V series: 260 – 900 VDC
– Can be connected in parallel
Brake chopper, brake power distributed over several amplifiers on the
same intermediate circuit
Internal brake resistor is standard, external brake resistor available on
request
Inverted rectifier with isolated current measurement and IGBT transis-
tors
Connection of synchronous servo motors, linear motors, asynchro-
nous motors
Fan installed on the following device types:
– 230 V series: 6 A, 10 A
– 480 V series: 3 A, 6 A
][Ueber_Merkmale_Entstoerfilter
Integrated noise suppression filters in accordance with EN 61800-3