beautypg.com

Control element, 1 supply voltage 24 vdc, 6wiring – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 112: 7 control element

background image

6.7

Control element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-22

6.7

Control element

6700

Control element

6-

6.7.1

Supply voltage 24 VDC

Supply voltage 24 VDC

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

Cable cross sections

Insulation material

Verdr_Versorgung_Warnung

][Verdr_Versorgung_24_V_DD5

][Verdr_Versorgung_24_V_protego_Sicherung_DD5

Use the following fuses.

WARNING!
Electric shock!
Safe electrical isolation must be ensured for the external power
supply that generates the supply voltage. Failure to do so could
result in electric shock. The power supplies must comply with
EN 60950-1, 05/2006, EN 61558-2-6, 11/1997.

Connector pin assignment

Connector X4

Pin

Designation

Description

1

+24 V

Supply voltage + 24 VDC

2

+24 V

Supply voltage + 24 VDC

3

DGND

Earth for supply voltage

4

DGND

Earth for supply voltage

Connection

Connected internally:
Pin 1 and 2 (24 V)
Pin 3 and 4 (DGND)

24 V connection isolated from exter-
nal power supply, e.g. with isolating
transformer

Noise suppression filters integrated
within the servo amplifier

Fuse

Device type

All

Type

Blow-out fuse or similar

Max. 8 AF

Fine wire fuse or
circuit breaker

X4

+24 V 1

DGND 3

+24 V 2

DGND 4

STO-ENABLE 5

4

L3

1

Servo Drive

X4

L1

L2

2

+24 V

DGND

PE

+24 V

+24 V

DGND

3