2 motor connection, 6wiring, 5 emc-compliant wiring – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 103

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-13
6.5
EMC-compliant wiring
6
Wiring
6.5.2.2
Motor connection
Motor connection
6-
][Verdr_Motorstecker
The cable shield for the motor cable is connected to the servo amplifier
housing via the shielding plate.
Use the ready-made motor cable from Pilz (accessory). However, if you
wish to wire your own motor connector, follow the instructions below:
Strip the outer cable sheath to ap-
prox. 20-25 mm in length,
without
damaging the braided shield.
Push the braided shield back over the
cable.
Shorten all the wires except for the
protective earth PE (green/yellow) by
approx. 20 mm. The PE wire is now
the longest.
Strip all the wires and fit end ferrules.
Wire the connector as shown in the
connection diagram.
Hook the shielded connection termi-
nal on to the shielding plate. Screw
the shielded connection terminal into
place. This provides ample, conduc-
tive contact between the braided
shield and the front plate.
Plug the connector into the slot on the
front of the servo amplifier.