4function description, 6 implementation of stop categories – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 80

4.6
Implementation of stop categories
4
Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-52
Wiring suggestion
Implementation of Category 1 E-STOP, control function with auxiliary
contactors
Fig. 4-19:
Stop Category 1
][Funktion_Stopp_Motorleistung
S1: On
S2: Off
S3: E-STOP
S1
S2
S3
BTB
or
M
M
M
This manual is related to the following products: