6wiring, 7 control element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 143

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-53
6.7
Control element
6
Wiring
Master-Slave mode
Connector pin assignment
Connector X5
Pin
Designation
Description
1
GND
Earth
2
n. c.
--
3
n. c.
--
4
A-
Channel A inverted
5
A+
Channel
A
6
B+
Channel
B
7
B-
Channel
B
inverted
8
n. c.
--
9
n. c.
--
n. c. = not connected
Connection
Output circuit
Output of incremental encoder sig-
nals
Always connect GND to the earth on
the control system
Twisted pair, shielded
Select R
T
in accordance with the ca-
ble impedance, typically 150
Ω
1
5
6
9
6
7
4
Servo Drive Slave
X5
5
B+
B-
A+
A-
GND
1
RT
Servo Drive Master
RT
X5
B+
B-
A+
A-
GND
6
7
4
5
1
This manual is related to the following products: