7commissioning, 2 commissioning the servo amplifier – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 165

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-9
7.2
Commissioning the servo amplifier
7
Commissioning
4. Enable axes
Switch on the mains voltage: Close the S3 switch “Mains on”
Close the S2 switch “HW-Enable”.
Press the
START
button in PScope.
An automatic software enable will be set. In PDrive, the
Enable axis
field
changes from
DISABLE
to
ENABLE
. The motor starts a reverse mode.
5. Perform tuning
Press
Tuning
in PScope and adjust the tuning parameters.
Ensure that the freely rotating motor is not yet connected to the work
machine.
This manual is related to the following products: