beautypg.com

4 intermediate circuit, 6wiring, 6 power element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 110

background image

6.6

Power element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-20

6.6.4

Intermediate circuit

Intermediate circuit

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

Cable cross sections

Insulation material

][Verdr_Zwischenkreis_DD5

The connections for the intermediate circuit are

Not short circuit and earth fault proof

Not reverse polarity protected.

][Verdr_Leiterquerschnitte_Zusatz

Connector pin assignment

Connector X8

Pin

Designation

Description

1

-DC

Intermediate circuit voltage -DC

3

+Rbext/+DC

Intermediate circuit voltage +DC

Connection

Output/input circuit

Intermediate circuit

Cable runs

200 mm:

Use unshielded single wires (2.5
mm²)

Cable lengths > 200 mm:
Use shielded cables.

X8

1 -DC

3 +RBext

4 +RBint

5 -RB

2 n.c.

1

RBext/+DC

3

Servo Drive

X8

-DC

Servo Drive

X8

1

3

Servo Drive

RBext/+DC

-DC