The servo amplifiers PMCtendo DD5 are designed to drive suitable
brushless, synchronous servo motors and asynchronous motors with
speed, torque and/or position control.

][Sicherheit_Bestimmung_Ausschluss

The following is deemed improper use:

Any component, technical or electrical modification to the servo am-
plifier

Use of the servo amplifier outside the areas described in this manual

Use of the servo amplifier outside the documented technical details
(see chapter entitled “Technical Details”)

Intended use includes making the installation and wiring EMC-compli-
ant. Please refer to the guidelines stated in this manual.

3.1.1

Hazard analysis

Hazard analysis

3-

][Sicherheit_Bestimmung_Gefahrenanalyse

The machine manufacturer must produce a hazard analysis for the ma-
chine. He must take appropriate measures to ensure that unexpected
movements do not lead to hazardous situations for either people or
equipment.

3.1.2

Electrical data

Electrical data

3-

][Sicherheit_Bestimmung_elektrisch_protego_D

Please note the electrical requirements stated in the chapters entitled
“Technical Details”, “Wiring” and “Function Description”.

3.1.3

Environmental conditions

Environmental conditions

3-

][Sicherheit_Bestimmung_Umgebung

Please note the following conditions for using the servo amplifier:

Operation of the servo amplifier is forbidden in the following condi-
tions:
– Potentially explosive areas
– Environments containing corrosive and/or conductive acids, alka-

line solutions, oils, fumes or dusts

– Where there is a direct connection to unearthed or asymmetrically

earthed mains supplies with U

N

> 240 V. See chapter entitled “Wir-

ing”, section on “Mains voltage”.

– On s

hips and o

ffshore installations