4.6
Implementation of stop categories
4
Function description
P
M
= (M
0
* n
n
) / 9550
where:
P
M
: Motor output [kW]
M
0
: Standstill torque [Nm]
n
n
: Rated speed [1/min]
Motor output P
M
Motor circuit brake resistor R
M
Up to 2.5 kW
27
Ω
(20 W) 1000 V
2.5 kW - 5 kW
8.2
Ω
(50 W) 1000 V
5 kW - 10 kW
2.7
Ω
(110 W) 1000 V
10 kW - 20 kW
1
Ω
(300 W) 1000 V
20 kW - 40 kW
0.33
Ω
(600 W) 1000 V