7commissioning, 4 messages/errors – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 171

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-15
7.4
Messages/errors
7
Commissioning
* = These warning messages result in a controlled shutdown of the drive
(braking with emergency ramp).
n10*
PSTOP
PSTOP limit switch operated
n11*
NSTOP
NSTOP limit switch operated
n12
Motor default values
loaded
ENDAT or HIPERFACE® only: Discrepancy
between the motor numbers saved in the en-
coder and amplifier, motor default values have
been loaded.
n13*
Expansion card
Problem with the 24V supply for the I/O ex-
pansion card
n14
SinCos feedback
SinCos commutation (wake & shake) incom-
plete, will be cleared if amplifier is enabled and
wake & shake is executed
n15
Table error
Fault as per speed/current table INXMODE 35
n16
Summary warning
Summary warning for n17 to n31
n17
Fieldbus Sync
CAN Sync is not logged in
n18
Multi-turn overflow
Maximum number of rotations exceeded
n19
Ramp restricted on
motion block
Value range exceeded for motion block data
n20
Invalid motion block
Invalid motion block
n21
Warning through
PLC program
Refer to PLC program
n22
Motor temperature
exceeded
The warning gives the user options for how to
respond before the "motor temperature" error
causes a controller shutdown.
n23
Sine/cosine encoder Warning threshold reached
n24
Digital inputs
Illogical configuration
n25-
n31
Reserved
Reserved
n32
Firmware beta ver-
sion
Firmware version has not been released
No.
Error message
Description