beautypg.com

2 motor with brake, 6wiring, 6 power element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 107

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-17

6.6

Power element

6

Wiring

Use the following fuses for F

N1

, F

N2

and F

N3

, depending on the device

type.

US types in brackets

x = S or S-R for mains voltage 480 V

x = N or N-R for mains voltage 230 V

6.6.2

Motor with brake

Motor with brake

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

Cable cross sections

Insulation material

][Verdr_Motor_protego_D

The motor and motor holding brake are connected to the same termi-
nal on the servo amplifier. The wires can be carried within the same
cable. Note: The wires for the motor holding brake must have sepa-
rate shielding.

The motor connection must be shielded appropriately.

Fuse

Device type

1.5 A, 3 A

6 A, 10 A

Blow-out fuse or similar

6 AT
(FRx-6)

10 AT
(FRx-10)

Connector pin assignment

Connector X9

Pin

Designation

Description

1

BR-

Brake-

2

BR+

Brake+

3

PE

Earth conductor

4

U2

Motor connection phase U

5

V2

Motor connection phase V

6

W2

Motor connection phase W

X9

PE
U2
V2
W2

BR-
BR+

3
4
5
6

1
2