6.5

EMC-compliant wiring

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-12

6.5.2.1

Shield connection on the front plate

Shield connection on the front plate

6-

][Verdr_Schirm_Front_DD5

Remove the outer cable sheath and
the braided shield to the required wire
length. Secure the wires with a cable
tie.

Remove the outer cable sheath to a
length of approx. 30 mm. Be careful
not to damage the braided shield.

Strip all the wires and fit end ferrules.

Use the cable ties to attach the cable
to the shielding plate on the side (1) or
bottom (3) of the servo amplifier.
Press the cable's braided shield firmly
against the shielding plate on the ser-
vo amplifier using a cable tie (2).

Alternatively you can use the shielded
connection terminals (4) (available as
an accessory). These hook into the
bottom shielding plate and guarantee
optimum contact between the shield
and the shielding plate.

(1)

(2)

(3)

(4)