beautypg.com

6wiring, 6 power element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 108

background image

6.6

Power element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-18

Connection

Output circuit

Motor with brake

Cable length

25m

Wires to the brake (BR+/BR-) should
be shielded separately

Connect the shielding on both ends

Cable runs > 25m to max. 50 m

Leakage currents on long cable runs
place a load on the servo amplifier's
output stage.

Wire the motor choke (accessories)
into the motor cable, close to the am-
plifier.

The wires to the brake (BR+/BR-)
should be shielded separately.

Connect the shielding on both ends.

1

2

Servo Drive

X9

BR-

BR+

M

3

4

5

6

PE

U2

V2

W2

1

2

Servo Drive

X9

BR-

BR+

M

3

4

5

6

PE

U2

V2