2overview, 1 unit structure – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 13
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-3
2.1
Unit structure
2
Overview
Integrated safety
Device safety
– Safe electrical isolation between mains voltage/motor connection
and control element, in accordance with EN 61800-5-1
– Soft start, overvoltage detection, short circuit protection, phase
failure monitoring
– Temperature monitoring of servo amplifier and motor (when using
Pilz motors with ready-made cables)
Protection of personnel and plant
– Safety function STO – Safe torque off
Single-channel without feedback: Up to PL d (Cat. 2) of
EN ISO 13849-1 and SIL CL 2 of EN/IEC 62061
Ueber_Merkmale_Erweiterungen_DD5
Expansion cards
1 slot for expansion cards:
– I/O
– PROFIBUS
– SERCOS I
I
– DeviceNet
Fieldbus junction box
CAN Adapter: Splits the combined RS232/CANopen interface on the
PMCtendo DD5 into one RS232 interface and two CANopen interfac-
es wired in parallel