beautypg.com

2overview, 1 unit structure – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 13

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-3

2.1

Unit structure

2

Overview

Integrated safety

Device safety
– Safe electrical isolation between mains voltage/motor connection

and control element, in accordance with EN 61800-5-1

– Soft start, overvoltage detection, short circuit protection, phase

failure monitoring

– Temperature monitoring of servo amplifier and motor (when using

Pilz motors with ready-made cables)

Protection of personnel and plant
– Safety function STO – Safe torque off

Single-channel without feedback: Up to PL d (Cat. 2) of
EN ISO 13849-1 and SIL CL 2 of EN/IEC 62061

Ueber_Merkmale_Erweiterungen_DD5

Expansion cards

1 slot for expansion cards:
– I/O
– PROFIBUS
– SERCOS I

I

– DeviceNet

Fieldbus junction box

CAN Adapter: Splits the combined RS232/CANopen interface on the
PMCtendo DD5 into one RS232 interface and two CANopen interfac-
es wired in parallel