5 establish communication pmctendo dd5 <-> pc, 6 set parameters for the servo amplifier, 7commissioning – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 162: 2 commissioning the servo amplifier

7.2
Commissioning the servo amplifier
7
Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-6
7.2.5
Establish communication PMCtendo DD5 <-> PC
Establish communication PMCtendo DD5 <-> PC
7-
][Inbetrieb_Kommunikation_protego_D
1. Switch on the personal computer
2. Start the terminal program PTerm
Establish a connection between the PC (COMx) and servo amplifier
(X6).
Communication parameters: Transmission rate = 38400, handshake =
Xon/Xoff
3. Start the commissioning software PDrive
Start up PDrive.
4. Establish communication between the PC and servo amplifier
Click on
PC <-> Connect Amplifier
.
The servo amplifier downloads the control parameters to the PC.
5. Do not enable the power element
In the service bar, click on the icon
.
The status appears as
DISABLE
under
Enable axis
.
7.2.6
Set parameters for the servo amplifier
Set parameters for the servo amplifier
7-
][Inbetrieb_Parametrieren_1_DD5
Please note the following requirements:
The servo amplifier must not be enabled (ENABLE = 0).
The mains voltage must be switched off.
The commissioning software PDrive must have been launched.
Set the basic parameter settings
1. In the project window, select
Setup -> Basic Setup
.
The "Basic Setup" window appears.
This contains information about the servo amplifier (hardware,
firmware, serial number, operating hours).
INFORMATION
Details descriptions of the software tools used below are availa-
ble on the Tools-CD.