6wiring, 7 control element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual
Page 145

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-55
6.7
Control element
6
Wiring
Output of SSI signals
Connector pin assignment
Connector X5
Pin
Designation
Description
1
GND
Earth
2
n. c.
--
3
n. c.
--
4
CLOCK
Pulse signal
5
CLOCK\
Pulse signal inverted
6
DATA
Channel
B
7
DATA\
Channel B inverted
8
n. c.
--
9
n. c.
--
n. c. = not connected
Connection
Output circuit
Output of SSI signals
Shield connection in the connector
Always connect GND to the earth on
the control system
Select RT in accordance with the ca-
ble impedance, typically 150
Ω
1
5
6
9
6
7
4
Servo Drive
X5
PLC
5
CLOCK
CLOCK\
DATA
DATA\
GND
1
GND
CLOCK
CLOCK\
DATA
DATA\
RT
RT
This manual is related to the following products: