beautypg.com

6wiring, 7 control element – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 145

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-55

6.7

Control element

6

Wiring

Output of SSI signals

Connector pin assignment

Connector X5

Pin

Designation

Description

1

GND

Earth

2

n. c.

--

3

n. c.

--

4

CLOCK

Pulse signal

5

CLOCK\

Pulse signal inverted

6

DATA

Channel

B

7

DATA\

Channel B inverted

8

n. c.

--

9

n. c.

--

n. c. = not connected

Connection

Output circuit

Output of SSI signals

Shield connection in the connector

Always connect GND to the earth on
the control system

Select RT in accordance with the ca-
ble impedance, typically 150

Ω

1

5

6

9

6

7

4

Servo Drive

X5

PLC

5

CLOCK

CLOCK\

DATA

DATA\

GND

1

GND

CLOCK

CLOCK\

DATA

DATA\

RT

RT