Elecraft K2 Owner's Manual User Manual
Page 93
92
E
LECRAFT
®
BFO Displays
Tap
B AN D -
to display the BFO setting for filter FL1, which will be
similar to BF1t110c. The 3-digit number is the BFO control
parameter. This number can be changed using the VFO knob, but
you'll use a different BFO-setting method described below. The letter
t
after BF1 is a reminder that the BF1 BFO frequency is always
used on transmit, which is important for SSB operation.
Whenever the BFO control parameter is displayed, you can tap
D I S P L AY
to show the actual BFO frequency in kHz. The VFO knob
can then be used to set the BFO directly. This method is used in the
filter-setup example.
Note: After changing the BFO setting, you can tap
A G C
to re-
measure and save the BFO information without switching filters.
This is useful if you want to try various BFO settings for a particular
filter to find the one with the best audio peak.
Other CAL FIL Operations
When you're in CAL FIL you can always tap
X F I L
to change to the
next filter, tap
M O D E
to change modes, and hold
C W R V
to switch
from CW normal to CW reverse. Whenever you switch modes or filters,
the K2 will first record your new settings, if they have been changed.
B AN D +
switches to the filter bandwidth display, and
B AN D -
switches
to the BFO display. Tapping
M E N U
exits CAL FIL and returns to the
normal display. (On exit from CAL FIL, changes are saved.)
Turning Selected Filters Off
FL2, 3, or 4 can be individually disabled. To turn off a filter, display the
filter bandwidth using CAL FIL, then set the bandwidth number to
O F F
. (To get to OFF, go to 0.00 first, then turn the VFO knob a bit
farther counter-clockwise.)