Secondary Menu Functions

To access the secondary menu, tap

M E N U

, then tap

D I S P L AY

. You'll

see SEC. All secondary menu functions are listed and described here.
Additional parameters accessed with

D I S P L AY

during

E D I T

mode are

marked (*); see below.

S L C H

Squelch level

R A T E S

R AT E

switch selections

DOT

Dot/space ratio (keying weight)

F P L Y

Fast Play switch selections

P O R T

RS232 interface on/off (Port Test*)

S P L T

S P L I T

,

R I T

,

X I T

configuration

P o 2 8

10 / 12 meter SSB power output limit

R T T Y

RTTY (data) mode control

RTC

Real-time clock control

RI T

RIT/XIT offset range (up to +/- 4.8 kHz)

ACC

Accessory output control

D 1 9

Leave at default (n) unless K60XV option installed

P A

K2/100 final stage mode selection (Fan Mode*)

TRN1-3/4-6

Transverter band setup (Parameter*)

D I S P L AY

Switch Usage in

E D I T

Mode: The

D I S P L AY

switch is

used to access supplemental parameters when editing certain menu
entries (marked "*" above). You will normally not need to change
these settings. Entries which use

D I S P L A Y

include:

Menu Entry

D I S P L AY

Usage

PORT

Sends an RS232 test message if PORT is ON

PA

Selects PA fan mode (see KPA100 manual)

T R N 1 - 6

Selects transverter parameters (see page 109)

D 1 9

Selects PA low-pass filter to use on 60 meters.
P A 6 0 = 80

(80 m filter) or PA60=40 (40/30 m

filter). See instructions in K60XV manual.

Squelch (SLCH)

Squelch defaults to OFF. You can set the threshold to 1-10,
corresponding to the S-meter's bargraph segments. Transmitting holds
squelch open for about 10 seconds.

Tuning Rate Selection (RATES)

The RATES menu entry lets you specify how the

R AT E

switch

works. The four options are:

3 N

3 rates, normal order (10/50/1000 Hz steps)

3 R

3 rates, reverse order (1000/50/10 Hz steps)

3 C

3 rates, CW optimized (10/20/1000 Hz steps)

2

2 rates (10/50 Hz steps only)

Keying Weight (DOT)

DOT

sets the internal keyer's dot/space ratio (keying weight). The

range is 0.90-1.40, roughly 90% to 140% of "normal" weighting.
The default is 1.10.

Fast-Play CW Messages (FPLY)

CW messages are normally played by tapping

M S G

, then

0

-

8

. During

contests, some operators prefer to have one-touch access, which we
refer to as Fast-Play.

To use Fast-Play: First, program

P F 1

or

P F 2

as FPon for use in

turning Fast-Play mode on/off. Next, use the FPLY menu entry to
select a switch group. For example, if you have FPLY 2-5 selected,
you can use

2

,

3

,

4

, and

5

for Fast-Play. (The

T AP

functions of these

switches won't be available in CW mode;

H O L D

functions are

unaffected.) When Fast-Play is on, the letter F will replace the mode
letter c once every few seconds as a reminder.

A tap of any Fast-Play switch will play its message buffer one time.
To auto-repeat, you must still use

M S G

as described on page 101.