2. Specifications

All measurements were made using a 14.0 V supply and 50-ohm load
unless otherwise indicated. Values are typical; your results will be
somewhat different. Specifications are subject to change without
notice. (See option manuals for additional specifications.)

General

Size

Cabinet

3.0" H x 7.9" W x 8.3" D

(7.5

x

20

x

21

cm)

Overall

3.4" H x 7.9" W x 9.9" D

(8.5

x

20

x

25

cm)

Weight

3.3

lbs.

(1.5

kg),

excluding

options

Supply voltage

9 to 15 VDC;
reverse-polarity protection;
internal self-resetting fuse

Current

drain,

Receive 120-150 mA in minimum-current

configuration; 180-250 mA typical


Transmit

1

2.0 A typical at 10 watts;
programmable current limiting

Frequency control

PLL synthesizer w/single VCO

covering 6.7-24 MHz in 10 bands;

fine

steps

via

DAC-tuned

reference

1

Current varies with band, supply voltage, configuration, and load

impedance. We recommend a minimum 3.5-amp power supply.

Frequency

ranges,

2

MHz

Basic kit

3.5-4.0, 7.0-7.3,

10.0-10.2,

14.0-14.5,

18.0-18.2,

21.0-21.6,

24.8-25.0,

28.0-28.8

160

m

(opt.)

1.8-2.0

60 m (opt.)

5.0-5.5

VFO

Stability

< 100 Hz total drift typ. from
cold start at 25° C

Accuracy

3

+/- 30 Hz over a 500 kHz range
(typ) when calibrated

Resolution 10

Hz

Tuning steps

10 Hz, 50 Hz, and 1000 Hz nominal

(other step sizes available via menu)

Memories

20 (10 assigned to 160-10 m

Bands;

10

general-purpose)

RIT/XIT range

+/- 0.6 to +/- 4.8 kHz (selectable);
10-40 Hz steps depending on range.

Fine RIT mode steps 2-3 Hz typ.

2

The K2 can receive well outside the indicated bands, but this extended range

is not specified or guaranteed. Transmit ranges may be limited for export to
some countries. The K2/100 (KPA100 option) limits transmit from 25-27.999
MHz to 10 watts or less.

3

See Frequency Calibration Techniques (page 105).