beautypg.com

Operator’s manual – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 86

background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

78 / SYSTEM CONFIGURATION

To activate Precharge:

1. At the Control Channel screen, enter a Precharge time. A Precharge

Time must be entered before the Precharge Ground Speed feature
displays on the Ground Speed Setup screen (Refer to Ground Speed
Setup section).

2. Press the Work Screen button and select the Speed Set button.
3. Enter a Precharge Ground Speed greater than 0.

IMPORTANT: Turn the master switch ON to activate the Precharge

feature.

NOTE: The master switch must be ON

to activate the Precharge
feature.

Delay Time

IMPORTANT: A Delay Time number MUST be entered as a negative

number (-5.0 seconds) for the system to identify
between a Delay Time or Precharge state.

With an Implement Lift Switch

Delay Time determines the length of time before the control channel will
start after the master switch has been turned ON and the implement switch
is in a lowered position.

• The system will immediately shutdown the channel when the

implement lift switch is in the raised position.

• The system will delay the channel shutdown if the master switch is

turned OFF and the implement is in the down position.

Without an Implement Lift Switch

When the Delay Time feature is utilized without an implement lift switch:

• The control channel will delay after the master switch has been turned

ON.

• A delay will also occur and then shutdown the control channel when

the master switch is turned OFF.

NOTE: Delay Time functionality may

work differently than described
above if the system has been
purchased direct from the
original equipment
manufacturer. Refer to the
manufacturer’s operator
manual for further instruction.

Flush Enable

Flush Enable is a manual override mode that opens the valve and
dispenses granular fertilizer, granular seed, or liquid material for a period of
time in relation to a user-defined flush speed. The Flush Enable feature can
only be activated when the tractor is stopped.

To activate Flush Enable:

1. Change Flush Disable to Enable. Flush Enable must be activated

before the Flush Ground Speed feature displays on the Ground Speed
Setup screen.

2. A Flush Ground Speed greater than 0 must be entered on the Ground

Speed setup screen for this feature to operate.