Operator’s manual, Start – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual
Page 146
OPERATOR’S MANUAL
IntelliAg PDC User 2 & 3
11001-1501-200811
138 / SYSTEM OPERATION
4. Engage hydraulics and run engine at normal speed until hydraulic fluid
is at operating temperature.
Implement will begin to operate after pressing the Start button.
Ensure that all persons and objects are away from the implement
to avoid personal injury.
5. Press the Start button. The seed meters will turn for 1 revolution, then
stop.
6. Pressing the Stop button will also terminate the test.
Figure 83
Fill Disk Screen for All Planter Controls
START
1. Lower the implement to operating position, engaging the implement
switch, if present and enabled.
2. With the hydraulic system engaged and the tractor at its normal
operating RPM, set the master switch to the On position. All enabled
control channels will begin controlling at the current ground speed. All
accumulators will begin recording data.
When the implement is down and the master switch in the On
position, the machine is fully operational. All necessary
precautions must be taken to ensure user safety. Failure to
practice all necessary caution may result in serious injury or
death.
STOP