OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 37

Figure 26
Material Setup Screen-Preset Method Enabled

PRESET METHOD DISABLED

When the Preset Method is disabled, the target rate on the Main Work
screen can be adjusted by pressing the Material Increment/Decrement
buttons. The target rate will increase or decrease based on the Inc/Dec %
value set at the Material Setup screen.

NOTE: Rate changes can only occur

on actively viewed control
channels.

Figure 27
Material Configuration Setup Screen-Preset Method Disabled

185

With Preset enabled, target
rate adjusts based on the
rates entered at the Material
Setup screen.

With Preset disabled,
target rate adjusts
based on the Inc/Dec %
rate set at the
Material Setup screen.
Value left of target
symbol is the difference
off of target rate.