beautypg.com

Operator’s manual, Row monitor setup – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 121

background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 113

ROW MONITOR SETUP

The Row Monitor Setup screen controls the parameters for:

• Material Name - monitor only
• High alarm delay
• Low alarm delay
• Population adjustment
• Population filter
• Row fail rate

1. From the Main Work screen, press the Row Monitor Setup button to

access the Row Monitor Setup screen.

NOTE: A material name will display on

the Row Monitor Setup screen
only when ALL seeding control
channels are disabled, no seed
rows are assigned to channels,
and material is set for Monitor
Only.

Figure 70
Row Monitor Setup Screen

IMPORTANT: For ground drive/nonhydraulic applications using the

planter monitor only feature, all seeding control
channels must be disabled, no seed rows assigned to
these channels, and a Material Name selected at the Row
Monitor Setup screen. Reference the Material
Setup-Monitor Only section for additional information.

MATERIAL NAME

Material Name only displays if there are NO seeding channels enabled and
no rows assigned to these channels. The Monitor Only selection must be
selected at the Material Configuration Setup screen.

This manual is related to the following products: