beautypg.com

Operator’s manual, Material setup constants - rpm control – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 57

background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 49

MATERIAL SETUP CONSTANTS - RPM CONTROL

The following constants on the Material Configuration Setup screen define
the parameters for RPM control.

NOTE: Refer to Channel Setup to link a

material to a channel.

Figure 34
RPM Control Material Setup screen

TARGET RATE

Target Rate establishes the desired rate of RPM.

MAX RATE

Maximum Rate establishes the maximum RPM the control will allow. Target
Rate cannot be incremented to a value greater than this established
maximum rate.

MIN RATE

Minimum Rate establishes the minimum RPM the control will allow. Target
Rate cannot be decremented to a value lower than this established
minimum rate.

INC/DEC %

The Increment/Decrement percent rate establishes the percentage of RPM
change each time the Increment/Decrement button is pressed on the Main
Work screen.

IMPORTANT: The maximum or minimum rates may not be reached if

the % increase or decrease, based off the target rate,
exceeds the maximum or minimum rate limits set.