Operator’s manual, Row assignment – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual
Page 110
OPERATOR’S MANUAL
IntelliAg PDC User 2 & 3
11001-1501-200811
102 / SYSTEM CONFIGURATION
ROW ASSIGNMENT
The Row Assignment screen automatically populates with the module
address and module type entered at the Module Configuration screen.
1. Press the Row Assignment button to access the Row Assignment
screen.
Figure 62
Row Assignment Screen
The following data items can be edited:
IMPORTANT: The # or Row data items for each listed module and the
Row #s value will automatically populate if the Auto
Config button is used to configure installed sensors.
# OF ROWS
The # of Rows column displays the total number of seed sensors that are
connected to each module. The Row #’s value is automatically configured
by Auto Config for proper row numbering for each module based upon the
module address value and # of rows.
A Module Next Page button will display if more than 12 modules are
connected. Press the Module Next Page button to display additional
modules.
NOTE: Only modules that support seed
sensors display on the Row
Assignment screen.
To edit # Of Rows data:
1. Enter the number of rows to be assigned to each module.
2. Press the Sensor Detect button to detect and test seed sensors. An
hour glass will appear in the upper right corner while the sensors are
tested.
+1
NXT MODULE