SYSTEM CONFIGURATION / 109
# OF PRESSURE/RPM SENSORS
The Number (#) of Pressure/RPM column displays the total number of RPM
or pressure sensors that are connected to each module. When a pressure
or RPM Sensor is entered into this column, the proper sensor numbering
sequence for each module is automatically entered into the Pressure/RPM
#’s column based upon the module address value.
RPM SETUP
The RPM Setup screen controls the parameters for each RPM sensor:
• Sensor type
• High alarm
• Low alarm
• High alarm delay
• Low alarm delay
• RPM constant
• RPM filter
• Disable control on low alarm
When an RPM sensor is entered at the Accessory Assignment screen, an
RPM Setup button displays.
1. Press the RPM Setup button to access the RPM Setup screen.
Figure 68
RPM Setup Screen
IMPORTANT: RPM sensors must be configured manually.
NOTE: Only modules that can support
accessory sensors are
displayed on the Accessory
Assignment screen.
HIGH ALARM
The High Alarm option sets the RPM value at which a high RPM warning
error is generated. The value is entered in RPM.