beautypg.com

Operator’s manual, Valve calibration - planter control – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 68

background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

60 / SYSTEM CONFIGURATION

VALVE CALIBRATION - PLANTER CONTROL

The Valve Calibration screen sets the machine hydraulic system
parameters and should be performed for best results. Each control channel
that is enabled requires a valve calibration.

At the Channel Setup screen, press the Valve Calibration button to access
the Valve Calibration screen.

NOTE: Verify disc speed high limit is

set correctly. Valve calibration
will try and obtain the high disc
speed.

Figure 39
Valve Calibration Screen - Planter Control

When the START key is engaged, the machine will become
operational. All necessary precautions must be taken to ensure
user safety. Failure to practice all necessary caution may result in
serious injury or death.

Hoppers are assumed to be empty for this calibration. If they are
loaded, material will be dispensed onto the ground.

To perform the Control Channel Valve Calibration:

1. Move the implement to the “raised” position.
2. Apply the tractor brakes and lock in the applied position.
3. Put the transmission in “park” or in a locked, neutral position.
4. Start the tractor and engage the hydraulic system, i.e. PTO or auxiliary

lever.

5. Run the engine at normal operating speed until the hydraulic fluid is at

normal operating temperature.

6. Press the Start button.

This manual is related to the following products: