Operator’s manual – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual
Page 49
OPERATOR’S MANUAL
IntelliAg PDC User 2 & 3
11001-1501-200811
SYSTEM CONFIGURATION / 41
MATERIAL SETUP CONSTANTS-GRAN SEED AND
GRAN FERTILIZER CONTROL
Material Setup parameters for Granular Seed and Granular Fertilizer using
hydraulic control systems.
NOTE: Refer to Control Setup to link a
material to a channel.
Figure 30
Granular Seeding Material Setup Screen
NOTE: Additional Material Setup
screen, selected by pressing
‘More”, only applies to Granular
Seed Control; not Granular
Fertilizer.
TARGET RATE
Target Rate establishes the desired rate of application in pounds per acre
(kg/Ha).
MAX RATE
Maximum Rate establishes the maximum application rate in pounds per
acre (kg/Ha) that the control will allow. Target Rate cannot be incremented
to a value greater than this established maximum rate.
MIN RATE
Minimum Rate establishes the minimum application rate in pounds per acre
(kg/Ha) that the control will allow. Target Rate cannot be decremented to a
value lower than this established minimum rate.
INC/DEC %
The Increment/Decrement percent rate establishes the percentage of
change of the entered target rate that will be applied each time the
Increment/Decrement button is pressed on the Main Work Screen.
IMPORTANT: The maximum or minimum rates may not be reached if
the % increase or decrease, based off the Target Rate,