beautypg.com

Operator’s manual – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 49

background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 41

MATERIAL SETUP CONSTANTS-GRAN SEED AND
GRAN FERTILIZER CONTROL

Material Setup parameters for Granular Seed and Granular Fertilizer using
hydraulic control systems.

NOTE: Refer to Control Setup to link a

material to a channel.

Figure 30
Granular Seeding Material Setup Screen

NOTE: Additional Material Setup

screen, selected by pressing
‘More”, only applies to Granular
Seed Control; not Granular
Fertilizer.

TARGET RATE

Target Rate establishes the desired rate of application in pounds per acre
(kg/Ha).

MAX RATE

Maximum Rate establishes the maximum application rate in pounds per
acre (kg/Ha) that the control will allow. Target Rate cannot be incremented
to a value greater than this established maximum rate.

MIN RATE

Minimum Rate establishes the minimum application rate in pounds per acre
(kg/Ha) that the control will allow. Target Rate cannot be decremented to a
value lower than this established minimum rate.

INC/DEC %

The Increment/Decrement percent rate establishes the percentage of
change of the entered target rate that will be applied each time the
Increment/Decrement button is pressed on the Main Work Screen.

IMPORTANT: The maximum or minimum rates may not be reached if

the % increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.

This manual is related to the following products: