SYSTEM OPERATION / 141
The following symbols illuminate in the bar graph area:
Figure 85
Row Indicator Symbols
AUTOPILOT STEERING NAVIGATION
Autopilot Steering Navigation can be engaged and disengaged from the
Main Work screen and displays swath # (AB0), cross-track error (0.00 IN),
age of correction (0.0 SEC), heading direction (360 degrees), and % swath
complete.
ACCUMULATORS
Some Data Item values can be reset to zero from the Main Work screen. An
accumulator displays (e.g., Area 1 Field, Seed Count, etc.) on the active
screen and can be reset to zero by placing a check mark in the box next to
the data item. Only accumulators on the currently-displayed screen can be
reset. Accumulators are reset independently and can only be reset when
the master switch is OFF. Once an accumulator has reached its maximum
value, it will roll over to 0.0.
POPULATION ROW SCAN
Pop Row Scan displays all active seed rows population in seeds per acre
(or seeds/Ha) for each detected seed sensor. The value to the left side
displays the current row number being scanned. The value on the right is th
epopulation data. The scans continue sequentially in four-second intervals
unless the rotary knob is used to select a particular ro wnumber for
continuous view. This Data Item displays on an entire ro wo fthe Work
screen.
SINGULATION AVERAGE POPULATION
Singulation Average displays the average percent seed singulation of the
rows that are configured for population. Singulation refers to the portion of
seeds planted individually, rather than in groups.
MATERIAL NAME
Active Material Name for a control channel created at the Control Channel
screen.
1
Row assignment
to channel
Planting at
desired rate
High Population
Low Population
Row Failure
X
Row off manually
or pattern
Blockage
Not planting
Master Switch off
!
Row off by control
and seeds detected
Row
Off
Off
Press to engage and
disengage
3
0 . 0 0
AC T
Reset box
0 . 0
5
KS
AC
0 %
MATRL 1