POP MIN ROW
Pop Min Row displays the seeding row with the minimum population in
seeds per acre (or seeds/Ha). The value to the left side displays the current
row number. The value on the right is the population data. This Data Item
will display on an entire row of the Work screen.
POP MAX ROW
Pop Max Row displays the seeding row with the maximum population in
seeds per acre (or seeds/Ha). The value to the left side displays the current
row number. The value on the right is the population data. This Data Item
will be displayed on an entire row of the Work screen.
POP AVG
Pop Avg displays the average population in seeds per acre (or seeds/Ha) of
all active seeding rows per channel.
NOTE: All Data Items are selected
from the Work Configuration
screen. Refer to the Work
Screen Configuration section
for setup instructions.
SPACING ROW SCAN
Spacing Row Scan scans all active seed rows and displays the spacing in
inches (cm) for each row as detected by the sensors. The value to the left
side displays the current row number. The value on the right is the
population data. The scans continue sequentially in four-second intervals
unless the rotary knob is used to select a particular row number for
continuous view. This Data Item displays on an entire row of the Work
screen.
SPACING MIN MAX ROW SCAN
Spacing Min Max Row Scan alternately displays the seeding rows with the
minimum and maximum spacing in inches (cm). The value to the left side is
the current row number. The value on the right is the spacing. Dwell time for
each display is four seconds. This Data Item displays on an entire row of
the Work screen.