beautypg.com

Wiring information for pos4000 interface board – Unitec POS4000/V2 User Manual

Page 97

background image

POS4000

Document

Number:

POS4003

89

Document Title:

POS4000/V2 Operations Manual

The correct communication wiring is pin 1 to 1, pin 2 to 2. The shield should be
connected to earth ground at the interface board (connector C pin 4). See the
wiring diagram in the back of this manual and the table on the following page for
more detail.

WIRING INFORMATION FOR POS4000 INTERFACE BOARD



CONNECTOR-PIN COMMUNICATIONS LINK TO POS4000 CONSOLE
C-1

<>

Pin 1 (RS485 -)

C-2

<>

Pin 2 (RS485 +)

C-3

<>

Pin 3 (Signal GND) (not connected)

C-4

<>

Earth Ground (connected to Earth manually or via Hard

wired Earth ground cable







CONNECTIONS TO CAR WASH CONTROLLER

D-1

>

Car Wash "IN-USE" Signal

D-2

>

Car Wash "IN-USE" Neutral

A1-8

>

Car Wash Voltage to activate wash functions

B-1

<

To car wash controller "Function 1"

B-2

<

To car wash controller "Function 2"

B-3

<

To car wash controller "Function 3"

B-4

<

To car wash controller "Function 4"

B-5

<

To car wash controller "Function 5"

B-6

<

To car wash controller "Function 6"

B-7

<

To car wash controller "Function 7"

B-8

<

To car wash controller "Function 8"

*** See next table for "Function" descriptions

CONNECTIONS TO CUSTOMER COIN BOX

A-7

>

Power for customer lights

A-6

<

"Out-of-Service" light

A-5

<

"Enter Wash" light (Code valid)

A-4

<

"Code Accepted / Wait" light

A-3

<

"Reenter Code" light (code invalid)

D-3

>

Quarter mechanism voltage pulse (credit)

D-4

>

Quarter mechanism voltage neutral

D-5

>

Bill mechanism voltage pulse (credit)

On POS4000 Interface boards with Version 6.6 Hardware the Pin
C-4 is connected internall

Note:

y to Signal Ground.