8.1 Pre-Installation Requirements






1. Conduit (3/4") from cashier (location of main console) to car wash entrance

console (location of customer keypad)

2. Conduit (3/4" minimum, 1" preferable) from car wash entrance console to car

wash controller

3. Dedicated duplex (120 Volts/60 Hz, 3 amps, grounded) receptacle at location

of main console. One is required for the console and one for the printer. The
socket outlet shall be installed near the equipment and shall be readily
acceptable. Ground hole of receptacle must be properly connected to Earth
Ground.

4. POS4000 main console, printer and wall transformer
5. POS4000 interface board with keypad

If your system comes with separate coin box installation
instructions then follow them for the coin box and use the following
references to POS4000 Console installation only.

Note:

6. POS4000 main console/interface cable (3 conductor, 22 gauge with shield)

7. Control wires from car wash controller to POS4000 interface board









When installing multi-Console or Multi-Bay configurations refe

Note:

r

to included drawings for instructions on daisy chaining the
communications cable. Never wire the communications in a STAR
configuration where splices occur at any point other than at the
Consoles or Entrance stands.


Never run the communications lines in the same conduit as

wires used in powerin

Note:

g the coin box or the carwash.

8.2 Wiring


The wall transformer plugs into a 3-prong earth grounded wall outlet, the
connector at the end of the cord attaches to the mating connector on the back of
the main console. This cord connects the power and Earth Ground connection to
the Console.

The main console and interface board are connected by a communication cable.