[CMD]
[SYSTEM SETUP]
[3]

(password

3)

[MENU UP/DOWN] until

ΑE-System setup MENU->" appears

[ENTER]
[MENU UP/DOWN] until "Enab/Disab Displays" appears
[ENTER]

[1]

[ENTER]

Enable

Displays


If your system was incorrectly configured for multiple displays and
you are disabling them, you must first power down then power up the
coin box before it will function properly.

Note:

6.2.14 Relay

Latching


This command is used to set the relay latching to Momentary Outputs (default),
or Latched outputs. When relay latching is disabled (momentary outputs), the
relays will pulse on for 1 second then all turn off once the customer enters a code
or the appropriate amount of cash. The relays will then pulse on again if the
customer upgrades the wash.

When the relay latching is enabled, the program relays will come on when the
customer activates the wash by entering a code or cash. The relays will then
stay on until a wash-in-use signal is inputted to the system, at which time the
outputs will all turn off.

6.2.15 Relay

Stacking


This command is used to enable relay stacking (default), disable relay stacking,
or set to no customer stacking.

When relay stacking is enabled, the program relays will not activate while the
wash-in-use signal is activated. The relays will wait until the wash-in-use signal
is off to activate the relays.