beautypg.com

3 programming the output relays, Programming the output relays – Unitec POS4000/V2 User Manual

Page 94

background image

POS4000

Document

Number:

POS4003

86

Document Title:

POS4000/V2 Operations Manual

7.3 Programming the Output Relays


It is possible for each of the 5 backup customer codes to activate a different relay
(or set of relays). After the change-relays password has been entered, the
interface will beep once and wait for you to define which relay(s) should be
activated when the first backup customer code is entered (see table on the next
page). After you press the keys that define which relays will activate (press only
one key at a time), press the 0 key to finalize your selections. The interface
board will beep twice to indicate that it is waiting for you to define the relays
associated with the second backup customer code. Repeat the process for all 5
backup customer codes.




Key OUTPUT

RELAY

1

1

2

2

3

3

4

4

5

5

6

6

7

1 pulse on Relay 1

8

2 pulses on Relay

1

9

3 pulses on relay 1

Example to define relays as follows:

Code

# Relays

1

1

2

1 + 4

3

2

4

2 + 4 + 5

5

2 pulses on 1 + 3

[4][3][5][3][9][2][1][0] (Change-relays password)