Unitec POS4000/V2 User Manual
Page 154
POS4000
Document
Number:
POS4003
146
Document Title:
POS4000/V2 Operations Manual
3
$6.00
$4.00
Discount 2 prices may be programmed as per your requirements.
If you are using group keys (tunnel wash) then use groups 1, 2, and 3,
then assign program and option keys to those groups as per POS4000
manual.
Modify the wash names as required. You may have to alter the price signage at the
buttons of a Hamilton coin box if your wash name assignments have changed.
Modify the wire connections from the coin box if the POS4000 wash assignments have
changed.
From the Ext POS menu-> of the System setup menu change set the following:
POS Type = 1 for Dresser Wayne, 2 for Gilbarco or Verifone.
See POS4000 manual for other Register types. Serial Baud rate
may also have to change for other manufacturers. Compare your
system configuration report to the Register Baud rate settings
POS Offset = 0 down (default) (this will be different if you are
using group keys)
POS Max Washes = 3 (set to 4 if using 4 washes)
Send Code Age : Disabled (this is enabled if Receipt at pump
shows an expiration date of code)
Reverse order : Enabled (new function in 7.10, reverses the order
of wash requested by register/pump)
After
the
last change is made, a printout should follow that looks like this. (Note if
using groups Feature returned will be G1, G2 etc).
Serial Interface = POS 2 (this may be different)
POS Feature offset = 0 down
POS Max Washes = 3 (or 4 if using 4 washes)
Send Code Age : Disabled
Reverse order : Enabled
EXT
Default
Wash
Disc
Feature
Requested Level
Returned Name
1
0
P3
Super
Wash
2
0
P2
Deluxe
Wash
3
0
P1
Express
Wash
4
0
P3
Super
Wash
5
0
P2
Deluxe
Wash
6
0
P1
Express
Wash
7
0
P3
Super
Wash
8
0
P2
Deluxe
Wash
9
0
P1
Express
Wash
10
0
P3
Super
Wash
11
0
P2
Deluxe
Wash