beautypg.com

Unitec POS4000/V2 User Manual

Page 154

background image

POS4000

Document

Number:

POS4003

146

Document Title:

POS4000/V2 Operations Manual

3

$6.00

$4.00

Discount 2 prices may be programmed as per your requirements.
If you are using group keys (tunnel wash) then use groups 1, 2, and 3,
then assign program and option keys to those groups as per POS4000
manual.


Modify the wash names as required. You may have to alter the price signage at the

buttons of a Hamilton coin box if your wash name assignments have changed.


Modify the wire connections from the coin box if the POS4000 wash assignments have

changed.

From the Ext POS menu-> of the System setup menu change set the following:


POS Type = 1 for Dresser Wayne, 2 for Gilbarco or Verifone.
See POS4000 manual for other Register types.
Serial Baud rate
may also have to change for other manufacturers. Compare your
system configuration report to the Register Baud rate settings
POS Offset = 0 down (default) (this will be different if you are
using group keys)
POS Max Washes = 3 (set to 4 if using 4 washes)
Send Code Age : Disabled (this is enabled if Receipt at pump
shows an expiration date of code)
Reverse order : Enabled (new function in 7.10, reverses the order
of wash requested by register/pump)

After

the

last change is made, a printout should follow that looks like this. (Note if

using groups Feature returned will be G1, G2 etc).

Serial Interface = POS 2 (this may be different)

POS Feature offset = 0 down
POS Max Washes = 3 (or 4 if using 4 washes)
Send Code Age : Disabled
Reverse order : Enabled

EXT

Default

Wash

Disc

Feature

Requested Level

Returned Name

1

0

P3

Super

Wash

2

0

P2

Deluxe

Wash

3

0

P1

Express

Wash

4

0

P3

Super

Wash

5

0

P2

Deluxe

Wash

6

0

P1

Express

Wash

7

0

P3

Super

Wash

8

0

P2

Deluxe

Wash

9

0

P1

Express

Wash

10

0

P3

Super

Wash

11

0

P2

Deluxe

Wash