5 display pos diags, 6 clear audit counts, Display pos diags – Unitec POS4000/V2 User Manual
Page 75: Clear audit counts
POS4000
Document
Number:
POS4003
67
Document Title:
POS4000/V2 Operations Manual
Example to set non-printer mode:
[CMD]
[SERVICE]
[6][2][7][4][7]
(password 4)
(Example to set non-printer mode cont.)
[MENU UP/DOWN] until "Set print to Display" is displayed
[ENTER]
[1] [ENTER]
to enable printing customer codes to display
6.5.5 Display POS Diags
This command is used in troubleshooting the connection to the external POS
device. Enabling it will cause the POS4000 display to show diagnostic messages
that may be useful to technicians or the Engineering division of Unitec. Do not
use this command unless directed to do so by a qualified person.
Example to configure the displaying of POS diagnostic messages:
[CMD]
[SERVICE]
[6][2][7][4][7]
(password 4)
(Example to enable the setting)
[MENU UP/DOWN] until "Display POS Diags" is displayed
[ENTER]
[1] [ENTER]
to enable the displaying of POS diagnostics
6.6 Clear Audit Counts
This command prints an accounting report like the list counts command (see
section 6.3), but it also clears the selected counter level after the report is
printed.
Three sets of the counters (shift, manager, and auditor) can be cleared. Each
level requires a different password to clear. The shift, manager and auditor
counts are cleared using passwords 1, 2, and 5 respectively.
Example to clear the Manager level:
[CMD]