6 rated data (devices for 400/500v mains), 1 rated data for 400 v mains voltage, Rated data (devices for 400/500v mains) – Lenze EVF9383 User Manual
Page 43: Rated data for 400 v mains voltage, Technical data
Technical data
Rated data (devices for 400/500V mains)
Rated data for 400 V mains voltage
3.6
3.6.1
l
3.6−1
EDSVF9383V EN 4.0−11/2007
3.6
Rated data (devices for 400/500V mains)
)
Note!
Types EVF9335 ... EVF9383 for 400 V/500 V mains voltage are
suitable for DC supply or DC−bus operation together with
controllers of the 9300 series.
3.6.1
Rated data for 400 V mains voltage
Basis of the data
Voltage
Frequency
Supply
3/PE AC 400 V
[U
N
]
340 V − 0 % ... 577 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
DC 565 V (alternatively)
[U
DC
]
DC 480 V − 0 % ... 800 V + 0 %
˘
Output voltage
[U
OUT
]
3 ~ 0 ... U
N
0 ... 300 Hz
9300
Mains current
1)
Typical motor power
ASM (4−pole)
Power loss
Type
I
r
[A]
P
N
[kW]
P
N
[hp]
P
V
[kW]
EVF9335−EVVxxx
2)
200
110
150
2.8
EVF9336−EVVxxx
2)
238
132
200
3.3
EVF9337−EVVxxx
2)
285
160
250
4.0
EVF9338−EVVxxx
2)
356
200
300
5.0
EVF9381−EVVxxx
2)
475
250
350
6.6
EVF9382−EVVxxx
2)
570
315
450
8.0
EVF9384−EVVxxx
2)
713
400
550
10.0
The currents for EVF9381 ... EVF9383 are to be considered as total currents of master and slave
1)
For a controller switching frequency of 2 kHz
2)
Device in variant V210, V240, V270 or V300
9300
Output currents
Rated current
Maximum current
2)
1 kHz
1)
2 kHz
1)
4 kHz
1)
1 kHz
1)
2 kHz
1)
4 kHz
1)
Type
I
N1
[A]
I
N2
[A]
I
N4
[A]
I
M1
[A]
I
M2
[A]
I
M4
[A]
EVF9335−EVVxxx
3)
210
210
210
315
315
315
EVF9336−EVVxxx
3)
250
250
250
375
375
375
EVF9337−EVVxxx
3)
300
300
270
450
450
405
EVF9338−EVVxxx
3)
375
375
330
560
560
495
EVF9381−EVVxxx
3)
500
500
500
750
750
750
EVF9382−EVVxxx
3)
600
600
540
900
900
810
EVF9384−EVVxxx
3)
750
750
660
1125
1125
990
The currents for EVF9381 ... EVF9383 are to be considered as total currents of master and slave
Bold print = Lenze setting
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change with an overcurrent time of 1 minute at a maximum
and a base load time of 2 minutes with maximally 75 % I
Nx
3)
Device in variant V210, V240, V270 or V300