2 diagnostics, Diagnostics, Troubleshooting and fault elimination – Lenze EVF9383 User Manual
Page 386

Troubleshooting and fault elimination
Display of operating data, diagnostics
Diagnostics
9.1
9.1.2
l
9.1−2
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0064 Utilization
0
{1 %}
150 Device utilisation I×t
l
Read only
l
Device utilisation of the last
180 s operating time
l
C0064 > 100 % triggers
warning OC5
l
C0064 > 110 % limits the ouput
current of the controller to
67 % of the maximum current
in C0022
^
8.2−25
^
8.2−40
C0150 Status word
Bit00
—
Bit08
Status code
Read only
Decimal status word for
networking via automation
interface (AIF)
l
Binary interpretation indicates
the bit states
See System
Manual
(extension)
Bit01
IMP
Bit09
Status code
Bit02
—
Bit10
Status code
Bit03
—
Bit11
Status code
Bit04
—
Bit12
Warning
Bit05
—
Bit13
Message
Bit06
n = 0
Bit14
—
Bit07
CINH
Bit15
—
9.1.2
Diagnostics
Display codes for diagnostics
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0093 Drive ident
Controller identification
l
Read only
0
Invalid
Defective power section
1
None
No power section
14
...
20
9335VC 400V
...
9383VC 400V
Display of the controller used
21
...
28
9334VC 500V
...
9383VC 500V
9321
...
9333
9321 VC
...
9333VC
C0099 S/W version
x.y
Software version
l
Read only
x
y
Main version
Subversion
Description