4 overview of monitoring functions, Overview of monitoring functions, Configuration – Lenze EVF9383 User Manual
Page 287
Configuration
Overview of monitoring functions
8
8.4
l
8.4−1
EDSVF9383V
EN 7.1−04/2012
8.4
Overview of monitoring functions
The responses of monitoring functions can be partly parameterised via codes ˘ in GDC in the parameter menu under
Monitoring ˘.
Monitoring
Possible responses
l Lenze setting
ü Setting possible
Error message
Description
Source
CoDe
TRIP
Message
Warning
Off
0071
CCr
System fault
Internal
l
x091
EEr
External monitoring (activated via DCTRL)
FWM
C0581
l
ь
ь
ь
Voltage supply
2020
OU
Overvoltage in the DC bus (C0173)
MCTRL
l
1030
LU
Undervoltage in the DC bus (C0173)
MCTRL
l
0107
H07
Internal fault (power section)
Internal
l
Communication
x061
CE0
Communication error on the automation interface (AIF)
AIF
C0126
ь
ь
l
x062
CE1
Communication error at process data input object CAN1_IN (monitoring time can be set
with C0357/1)
CAN1_IN
C0591
ь
ь
l
x063
CE2
Communication error at process data input object CAN2_IN (monitoring time can be set
with C0357/2)
CAN2_IN
C0592
ь
ь
l
x064
CE3
Communication error at process data input object CAN3_IN (monitoring time can be set
with C0357/3)
CAN3_IN
C0593
ь
ь
l
x065
CE4
BUS−OFF state of the system bus (CAN)
(too many faulty telegrams)
CAN
C0595
ь
ь
l
Temperatures / sensors
0050
OH
Heatsink temperature > 85° C
MCTRL
l
x053
OH3
Motor temperature > 150° C
MCTRL
C0583
ь
ь
l
x054
OH4
Heatsink temperature > C0122
MCTRL
C0582
l
ü
x057
OH7
Motor temperature > C0121
MCTRL
C0584
l
ü
x058
OH8
Motor temperature across inputs T1 and T2 is too high.
Please note: In the case of "Warning" (C0585 = 2) or "Off" (C0585 = 3), the drive can be
destroyed if the fault is not eliminated in time!
MCTRL
C0585
ь
ь
l
x086
Sd6
Thermal sensor error at motor (X7 or X8)
MCTRL
C0594
ь
ь
l
x110
H10
Thermal sensor error at heatsink
FWM
C0588
l
1)
1)
x111
H11
Thermal sensor error in the device interior
FWM
C0588
l
1)
1)
Motor / feedback system
0011
OC1
Motor cable overcurrent
MCTRL
l
0012
OC2
Motor cable earth fault
MCTRL
l
0013
OC3
Overload at acceleration or deceleration
MCTRL
l