Configuration
Function blocks
Internal motor control with V/f characteristic control (MCTRL1)
8.2
8.2.6
l
8.2−29
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0078 Tn slip CTRL
100
1
{1 ms}
6000 Integral−action time of slip
controller
l
Filter time for slip
compensation (C0021)
l
Only active with V/f
characteristic control
^
8.2−25
C0086
s
Mot type
à
^ Motor selection list
Motor type selection
à
depending on the controller
used
l
Motor selection in C0086 sets
the corresponding parameters
in C0021, C0022, C0081,
C0087, C0088, C0089, C0090,
C0091
^ 6.6−1
C0087
s
Mot speed
à
50
{1 rpm}
36000 Rated motor speed
à
depending on C0086
l
Motor selection in C0086 set
the corresponding rated motor
speed in C0087
l
Change of C0087 sets
C0086 = 0
^ 6.6−1
C0089
s
Mot frequency
à
10
{1 Hz}
5000 Rated motor frequency
à
depending on C0086
l
Motor selection in C0086 sets
the corresponding rated motor
frequency in C0089
l
Change of C0089 sets
C0086 = 0
^ 6.6−1
C0090
s
Mot voltage
à
0
{1 V}
1000 Rated motor voltage
à
depending on C0086
l
Motor selection in C0086 sets
the corresponding rated motor
voltage in C0090
l
Change of C0090 sets C0086 =
0
^ 6.6−1
C0095
s
Mot Io
à
0.0
{0.1 A}
1000.0 Motor magnetising current
à
dependent on C0086, C0088
and C0091
l
Change of C0086 sets C0095 to
the Lenze setting
l
Change of C0095 sets
C0086 = 0
^ 6.6−1
C0105 QSP Tif
5.00
0.00
{0.01 s}
999.90 Quick stop deceleration time
l
The deceleration time refers to
a speed variation of C0011 ... 0
^
8.2−25
^
8.2−40
C0107 holding time
0.00
0.00
{0.01 s}
9999.90 Hold time for automatic DC
injection braking (Auto−GSB)
^
8.2−25
^
8.2−40
C0143 limit 2 kHz
0.0
0.0
{0.1 Hz}
20.0 Speed−dependent switching
threshold
l
Threshold for automatic
switching frequency reduction
l
The controller changes
automatically to 2 kHz when
this value falls below the
threshold
^
8.2−25
^
8.2−40