Configuration – Lenze EVF9383 User Manual
Page 246
Configuration
Function blocks
Internal motor control with V/f characteristic control (MCTRL1)
8.2
8.2.6
l
8.2−30
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0234 damp value
20
−100
{1 %}
100 Influence of the oscillation
damping, function block MCTRL
l
Minimising a tendency to
oscillation of the drive
l
Influences the tendency to
oscillation of the drive
l
When C0025 >1 and C0006 = 1,
C0234 is set to 0
^
8.2−25
^
8.2−40
C0235 damping
2
1
{1 ms}
600 Filter time of the oscillation
damping, function block MCTRL
l
Filter time for the internal
signal for oscillation damping
^
8.2−25
^
8.2−40
C0236 damp limit
1.0
0.0
{0.1 Hz}
20.0 Limit value of oscillation damping,
function block MCTRL
l
Limit value for the internal
signal of oscillation damping
C0890
s
CFG: N−SET
5050 NSET−NOUT
^ Selection list 1
Configuration of analog input
signal, function block MCTRL
l
Speed setpoint
^
8.2−25
^
8.2−40
C0900
s
CFG: QSP
10250 R/L/Q−QSP
^ Selection list 2
Configuration of digital input
signal, function block MCTRL
l
HIGH = drive performs quick
stop
^
8.2−25
^
8.2−40
C0903
s
CFG: BOOST
5015 MCTRL−BOOST
^ Selection list 1
Configuration of analog input
signal, function block MCTRL
l
Boost of the motor voltage
^
8.2−25
C0904
s
CFG: DC−BREAK
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block MCTRL
l
HIGH = Motor is braked
^
8.2−25
^
8.2−40
C0905 DIS: DC−BREAK
0
1 Function block MCTRL
l
Display of the signal linked in
C0904
C0906
−199.99
{0.01 %}
199.99 Function block MCTRL
l
Display of the signals linked in
C0890, C0891, C0892, C0893,
C0901 and C0903
^
8.2−25
^
8.2−40
1 DIS: N−SET
2 DIS: M−ADD
3 DIS: LO−M−LIM
4 DIS: HI−M−LIM
5 DIS: I−SET
6 DIS: BOOST
C0907
0
1 Function block MCTRL
l
Display of the signals linked in
C0899, C0900 and C0902
1 reserved
2 DIS: N/M−SWT
3 DIS: QSP
4 DIS: I−LOAD
C0909 speed limit
1
1
+/− 175 %
Speed limitation, function block
MCTRL
l
Limitation of direction of
rotation for the speed setpoint
^
8.2−25
^
8.2−40
2
0 ... 175 %
3
−175 ... 0 %
C0910
s
CFG: VP−ADAPT
1006 FIXED100%
^ Selection list 1
Configuration of analog input
signal, function block MCTRL
l
Gain adaptation of the speed
controller
l
If the gain is varying, join to
CURVE−OUT of FB CURVE
^
8.2−25
^
8.2−40
C0911 DIS: VP−ADAPT
−199.99
{0.01 %}
199.99 Function block MCTRL
l
Display of the signal linked in
C0910