Configuration – Lenze EVF9383 User Manual
Page 225
Configuration
Function blocks
Master frequency output (DFOUT)
8.2
8.2.3
l
8.2−9
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0540
s
Function
0
Function selection, function block
DFOUT
l
Output signal at X10
^
8.2−8
0
Analog input
Analog input
Signal at DFOUT−AN−IN is output.
Zero track can be input externally.
1
PH diff input
Phase difference
input
Signal at DFOUT−DF−IN is output.
Zero track can be input externally.
2
Not assigned
3
Not assigned
4
X10 = X9
X9 is output on
X10
The input signals are buffered
C0030 is without function
5
X10 = X8
X8 is output on
X10
C0541
s
CFG: AN−IN
5001 MCTRL−NACT
^ Selection list 1
Configuration of analog input
signal, function block DFOUT
l
Signal in [%] of C0011
C0542
s
CFG: DF−IN
1000 FIXEDPHI−0
^ Selection list 4
Configuration of input signal,
function block DFOUT
l
Speed signal
C0544
s
CFG: SYN−RDY
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block DFOUT
l
DFOUT−SYN−RDY = HIGH:
Generating a zero pulse
C0545 PH offset
0
0
{1 inc.}
65535 Phase offset, function block
DFOUT
l
Displacing the zero pulse
generated via DFOUT−SYN−RDY
by up to 360 °
l
1 rev. = 65535 inc (360 °)