3 incremental encoder with htl level at x9, Incremental encoder with htl level at x9, Wiring of the standard device – Lenze EVF9383 User Manual
Page 113
Wiring of the standard device
Wiring of the feedback system
Incremental encoder with HTL level at X9
5.8
5.8.3
l
5.8−3
EDSVF9383V EN 7.1−04/2012
5.8.3
Incremental encoder with HTL level at X9
Field
Values
Connection at drive controller
Connector: Pin, 9−pole, Sub−D
Connectable incremental
encoder
Incremental encoder with HTL−level
l
Two−track with inverse signals and zero track
l
Two−track without inverse signals and zero track
Input frequency
0 ... 200 kHz
Current consumption
5 mA per channel
Supply of incremental encoder External voltage source
Internal voltage source
(X9/4, X9/5)
5 V DC / max. 200 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
B
GND
Z
1
2
3
4
5
6
7
8
9
A
X9
< 50 m
A
B
Z
+
–
A
A
B
Z
B
Z
9300VEC020
Fig. 5.8−2
Connection of incremental encoder with HTL level
Signals for CW rotation
External voltage source for the incremental encoder
Cores twisted in pairs
X9 − Incremental encoder with HTL level
Connector: Pin, 9−pole, Sub−D
Pin
1
2
3
4
5
6
7
8
9
Signal
B
A
A
+5 V
GND
Z
Z
−
B
0.14 mm
2
(AWG 26)
1 mm
2
(AWG 18)
0.14 mm
2
(AWG 26)
)
Note!
Connecting the two−track incremental encoder without inverse
signals (at HTL level):
ƒ
Set signal A on pin X9/2 (A) and signal B on pin X9/9 (B).
ƒ
Wire pin X9/3 (A) and X9/1) (B) with the positive pole of the
external voltage source for the incremental encoder.
Technical data