2 oscillation damping, Oscillation damping – Lenze EVF9383 User Manual
Page 187
Optimising the operating behaviour
Oscillation damping
6.11
6.11.2
l
6.11−3
EDSVF9383V EN 7.1−04/2012
6.11.2
Oscillation damping
Suppressing no−load oscillations in case of:
ƒ Drives with different rated power of controller and motor, e. g. when
operating with high switching frequency and the power derating
involved.
ƒ Operation of higher−pole motors.
ƒ Operation of three−phase AC drives > 10 kW.
Compensation of resonances in the drive kit:
ƒ Certain asynchronous motors may show this behaviour above
1
/
3
of
the rated speed (
1
/
3
× n
n
). This may result in an unstable operation
(current and speed variations).
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0234 damp value
20
−100
{1 %}
100 Influence of the oscillation
damping, function block MCTRL
l
Minimising a tendency to
oscillation of the drive
l
Influences the tendency to
oscillation of the drive
l
When C0025 >1 and C0006 = 1,
C0234 is set to 0
^
8.2−25
^
8.2−40
C0235 damping
2
1
{1 ms}
600 Filter time of the oscillation
damping, function block MCTRL
l
Filter time for the internal
signal for oscillation damping
^
8.2−25
^
8.2−40
C0236 damp limit
1.0
0.0
{0.1 Hz}
20.0 Limit value of oscillation damping,
function block MCTRL
l
Limit value for the internal
signal of oscillation damping
Description